- The GT-6014-AM3 is specifically designed to determine the folding endurance of paper and cardboard.
- The specimen, held under tension by the upper clamp and subjected to repeated backward and forward folding by the lower clamp, is folded until fracture occurs. The number of folds required to break the specimen is recorded to evaluate its folding endurance.
-
Standards
- JIS-P8115
- TAPPI-T-511-OM-2008
- ASTM D2176-2016
- GB/T457-2008 5.1
- ISO 5626:1993
- SJ/T 11140-2012 6.12
Principle
The GT-6014-AM3 is specifically designed to determine the folding endurance of paper materials. It simulates repeated folding under real-world conditions to assess their ability to withstand folding.
Applicability:
Well-suited for production, quality assurance, and research in paper and cardboard applications.
Specimen securing clamps:
The two ends of the specimen are secured with upper and lower clamps, ensuring stability during testing.
Tensioning clamp:
With tension applied by the clamp, the specimen is subjected to a specific stress during testing, simulating real-world conditions under tension.
Repeated folding:
The lower clamp features backward and forward folding, replicating the way paper or cardboard folds in real-world conditions.
Fold counter:
Automatically records the number of folds, ensuring accurate test results and minimizing human error.
Quality assurance:
Helps manufacturers verify that their paper or cardboard products meet specific standards or testing requirements, ensuring the required level of folding endurance.
Product design improvement:
Provides valuable insights into the folding endurance of paper or cardboard materials during product development, assisting manufacturers in improving product and material design.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-

Independent motor drive
Each testing station is equipped with its own motor drive system, allowing samples to be tested under different conditions.

Multi-station
Allows multiple specimens to be tested simultaneously, enhancing test efficiency without interference.

High efficiency
The test angle can be set directly on the touchscreen controller without complicated setup, minimizing time for angle adjustment.
-
左右滑動看表格
*Product design and specifications are subject to change without notice.Conformance SJ/T 11140-2012 6.12 GB/T 457-2008 5.1, JIS P8115-2001, TAPPI-T511-OM 2008, ISO 5626:1993, ASTM D2176-2016 ControllerTouchscreenTouchscreen Test station 3 3 Folding angle 90°±2° 135±2° Folding speed 6 cycle/sec (one 90° folding = one cycle) 175±10 cpm Test load2.5N4.91, 9.81, 14.72N Drive system Servo motor (one motor per clamp) Servo motor (one motor per clamp) Power 1∮ AC220V 50/60Hz (or specify) 1∮ AC 220V 50/60Hz (or specify) Specifications Radius of curvature+specimen thickness clamping range (optional) Radius of curvature+specimen thickness clamping range (optional) ※Three sets included as standard; additional sets must be purchased separately ※Three sets included as standard; additional sets must be purchased separately Radius of curvature (mm)Specimen thickness clamping range (mm) Radius of curvature (mm)Specimen thickness clamping range (mm) 0.5 Customer-specified 0.38 0~0.25 1.0 0.5 0.25~0.5 3.5 0.8 0.5~0.75 1 0.75~1 1.51~1.25 -
-
Details
Standards
- JIS-P8115
- TAPPI-T-511-OM-2008
- ASTM D2176-2016
- GB/T457-2008 5.1
- ISO 5626:1993
- SJ/T 11140-2012 6.12
Principle
The GT-6014-AM3 is specifically designed to determine the folding endurance of paper materials. It simulates repeated folding under real-world conditions to assess their ability to withstand folding.
Applicability:
Well-suited for production, quality assurance, and research in paper and cardboard applications.
Specimen securing clamps:
The two ends of the specimen are secured with upper and lower clamps, ensuring stability during testing.
Tensioning clamp:
With tension applied by the clamp, the specimen is subjected to a specific stress during testing, simulating real-world conditions under tension.
Repeated folding:
The lower clamp features backward and forward folding, replicating the way paper or cardboard folds in real-world conditions.
Fold counter:
Automatically records the number of folds, ensuring accurate test results and minimizing human error.
Quality assurance:
Helps manufacturers verify that their paper or cardboard products meet specific standards or testing requirements, ensuring the required level of folding endurance.
Product design improvement:
Provides valuable insights into the folding endurance of paper or cardboard materials during product development, assisting manufacturers in improving product and material design.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-
Features

Independent motor drive
Each testing station is equipped with its own motor drive system, allowing samples to be tested under different conditions.

Multi-station
Allows multiple specimens to be tested simultaneously, enhancing test efficiency without interference.

High efficiency
The test angle can be set directly on the touchscreen controller without complicated setup, minimizing time for angle adjustment.
-
Specifications
左右滑動看表格
*Product design and specifications are subject to change without notice.Conformance SJ/T 11140-2012 6.12 GB/T 457-2008 5.1, JIS P8115-2001, TAPPI-T511-OM 2008, ISO 5626:1993, ASTM D2176-2016 ControllerTouchscreenTouchscreen Test station 3 3 Folding angle 90°±2° 135±2° Folding speed 6 cycle/sec (one 90° folding = one cycle) 175±10 cpm Test load2.5N4.91, 9.81, 14.72N Drive system Servo motor (one motor per clamp) Servo motor (one motor per clamp) Power 1∮ AC220V 50/60Hz (or specify) 1∮ AC 220V 50/60Hz (or specify) Specifications Radius of curvature+specimen thickness clamping range (optional) Radius of curvature+specimen thickness clamping range (optional) ※Three sets included as standard; additional sets must be purchased separately ※Three sets included as standard; additional sets must be purchased separately Radius of curvature (mm)Specimen thickness clamping range (mm) Radius of curvature (mm)Specimen thickness clamping range (mm) 0.5 Customer-specified 0.38 0~0.25 1.0 0.5 0.25~0.5 3.5 0.8 0.5~0.75 1 0.75~1 1.51~1.25 -
Video